Download Print this page
Theben RAMSES BLE OT 8509150 Manual
Theben RAMSES BLE OT 8509150 Manual

Theben RAMSES BLE OT 8509150 Manual

Clock thermostat

Advertisement

Quick Links

Clock thermostat
EN
RAMSES BLE OT
8509150
1. Basic safety information
NOTE
Connection and installation should only be carried
¾
¾
out by a qualified electrician!
Before installation/dismounting, disconnect the
¾
¾
power supply!
The clock thermostat conforms with EN 60730-2-9 if
correctly installed
Corresponds to type 1 STU in accordance with IEC/EN
60730-2-7
Operation and programming only via RAMSES BLE app
With external input (SELV, programmable)
2. Proper use
Heating control for time-dependent monitoring and
control of room temperature in single-family houses,
offices etc.
Use in dry rooms with normal levels of domestic
cleanliness
Disposal
Dispose of device in environmentally sound manner
¾
3. Installation
Mounting the clock thermostat
Electrostatic discharge!
Caution, sensitive electronic components!
When fitting, observe ESD safety measures (elect-
rostatic discharge).
!
Position the clock thermostat on an internal wall, at
about eye level.
!
Avoid drafts or heat emission.
L For wall mounting
307347
Attach the mounting plate above the wall outlet of the
¾
OpenTherm line .
Engage and wire the circuit board carrier .
¾
First, hook in the upper part of the clock thermostat on top,
¾
then engage .
Put on the cover .
¾
Dismounting the clock thermostat
Using a screwdriver, loosen the front panel at the two side
¾
and bottom openings .
Then release the catches on the left and right and remove
¾
the upper part of the housing .
Loosen the plug-in connectors and press the circuit board
¾
carrier together at the top and bottom .
Remove the circuit board carrier through the front.
¾
4. Connection
The power supply from the thermostat to the boiler is
provided via OpenTherm.
The two-wire connection (OpenTherm) is not polarised,
i.e. the wires can be connected to the boiler as required.
!
Disconnect the boiler from mains supply before connec-
ting the thermostat.
!
Faulty connections will damage the device.
!
Without interference, the bus line can be extended up to
50 m.
!
In order to eliminate the possibility of EMC interference,
always lay the feed of the supply voltage separate from
the mains cables.
1

Advertisement

loading

Summary of Contents for Theben RAMSES BLE OT 8509150

  • Page 1 307347 Clock thermostat RAMSES BLE OT 8509150    1. Basic safety information NOTE Connection and installation should only be carried ¾ ¾ out by a qualified electrician! Before installation/dismounting, disconnect the ¾ ¾ power supply! • The clock thermostat conforms with EN 60730-2-9 if correctly installed •...
  • Page 2 Terminal layout 6. Settings and functions – operation via Theben app Is my smartphone BLE capable? 1 OT Download Bluescan app for Android and iOS † ¾ 2 OT 3 ext. input The app can be used to check whether a device is BLE capa- 4 ext.
  • Page 3 Open the app † ¾ ▻ Window with offline mode/assign appears Press the button on RAMSES BLE OT for 3 s (green LED at † ¾ RAMSES BLE OT flashes) Press Assign † ¾ ▻ Device list appears Select device and press ok †...
  • Page 4 Settings When connected to a modulating heating Press Settings † ¾ ▻ A window will open • In the room-dependent version, the room set tempera- ture is used for direct control. P band (0.5 K–2.5 K) control range I share (1–20) integral share in minutes: –...
  • Page 5 3. External input Heating HVAC base HVAC end P -adjust- Frost type point point ment/ line The external input can be configured for various external reduction sensors. 90 / 70 30 °C 85 °C 15 °C 3 °C Input is active, therefore do not use external voltage. system The connected contact must be floating and electrically 70 / 50...
  • Page 6: Technical Data

    This function is used to carry out the legally required emission 8. Contact measurements (off, partial load, full load). It is automatically switched off after 30 min. Theben AG Hohenbergstr. 32 7. Setting TSP parameters (Transparent Slave Parameters) 72401 Haigerloch...