Setup
Operating Instructions 650-16 - 02.0 - 08/2016
5.
Screw the setpoint transducers (1) and (7) on to the frame
brace (2). Distance between the floor and the upper edge of
the frame brace (2): 290 mm.
6.
Screw the cable duct (8) (30 x 30 x 250 mm) for the setpoint
transducer cables on to the frame brace (2).
7.
Turn the adjusting screw (6) to ensure that the frame stands
securely. The frame must stand with all four feet on the floor.
8.4
Pre-assembling the table top
Fig. 71: Pre-assembling the table top
①
②
③
④ ⑤
To pre-assemble the table top:
1.
Turn the table top (1).
2.
Screw on the drawer (2) and its brackets
(chipboard screws 3.5 x 17).
3.
Screw on the knee switch (3).
4.
Screw on the sewing light transformer (4).
5.
Screw on the main switch (5)
(chipboard screws 5 x 30).
6.
Screw on the cable duct (6) (40 x 40 x 200 mm long)
(chipboard screws 3.5 x 17).
⑩
⑨
⑥
⑧
⑦
111