X524 Electronics Power Supply - Siemens SINAMICS Equipment Manual

Medium-voltage drives, supplementary component descriptions
Hide thumbs Also See for SINAMICS:
Table of Contents

Advertisement

Terminal Modules
5.2 Terminal Module TM31
NOTICE
Damage to motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
● Connect a KTY temperature sensor with the correct polarity.
Electric shock in the event of voltage flashovers at the temperature sensor
Voltage flashovers in the signal electronics can occur in motors without safe electrical
separation of the temperature sensors.
● Use temperature sensors that comply with the specifications relating to protective
● If safe electrical separation cannot be guaranteed (e.g. for linear motors or third-party
5.2.2.7

X524 Electronics power supply

Table 5-15
Type: Screw terminal 2
The maximum cable length that can be connected is 30 m.
Note
The two "+" and "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
66
WARNING
separation.
motors), use a SME120 or SME125 Sensor Module External or the TM120 Terminal
Module.
X524: Electronics power supply
Terminal
+
+
+
M
M
Designation
Electronics power supply
Electronics power supply
Electronics ground
Electronics ground
Technical data
Voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption: max. 1.7 A
(including DRIVE-CLiQ, digital outputs
and auxiliary voltages)
Max. current via the jumper in the con‐
nector: 20 A (15 A according to UL/CSA)
Supplementary component descriptions
Manual, 06/2019