Beater Rotation; Refrigerant - Taylor 336 Original Operating Instructions

Soft serve freezer
Hide thumbs Also See for 336:
Table of Contents

Advertisement

sheathed cord (Code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals and
protect the insulation of the conductors from abrasion.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent, or similarly qualified
person in order to avoid a hazard.

Beater Rotation

Beater rotation must be clockwise as viewed
looking into the freezing cylinder of any model freezer.
Note:
The following procedures should be performed
by a Taylor service technician.
To correct rotation on a three-phase unit, interchange any
two incoming power supply lines at freezer main terminal
block only.
To correct rotation on a single-phase unit, change the
leads inside the beater motor. (Follow the diagram
printed on the motor.)
Electrical connections are made directly to the terminal
block provided in the main control box located behind the
service panel.

Refrigerant

In consideration of our environment, Taylor
proudly uses only earth friendly HFC refrigerants. The
HFC refrigerant used in this unit is R404A. This
refrigerant is generally considered non-toxic and non-
flammable, with an Ozone Depleting Potential (ODP) of
zero (0). However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion.
Use only R404A refrigerant that conforms to
To the Installer
the AHRI standard 700 specification. The use of any
other refrigerant may expose users and operators to
unexpected safety hazards.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
Taylor reminds technicians to be aware of government
laws regarding refrigerant recovery, recycling, and
reclaiming systems. If you have any questions regarding
these laws, please contact the factory Service
Department.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
Model 336, 338, 339
TO THE INSTALLER
1-3