OPERATOR'S CHECKLIST
If your machine is equipped with an auxiliary
refrigeration system, check the auxiliary
condenser for accumulation of dirt and lint. Dirty
condensers will reduce the refrigeration capacity
of the mix hopper. Condensers must be cleaned
monthly with a soft brush. Never use
screwdrivers or other metal probes to clean
between the fins.
Caution: Always disconnect electrical power
prior to cleaning the condenser.
If your machine is water cooled, check the water
lines for kinks or leaks. Kinks can occur when the
machine is moved back and forth for cleaning or
maintenance purposes. Deteriorated or cracked
water lines should be replaced only by a Taylor
service technician.
7
7-2

Winter Storage

If the place of business is to be closed during the winter
months, it is important to protect the freezer by following
certain precautions, particularly if the building is subject
to freezing conditions.
Disconnect the freezer from the main power source
to prevent possible electrical damage.
On water-cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out
any water remaining in the condenser. This is
extremely important. Failure to follow this
procedure may cause severe and costly damage to
the refrigeration system.
Your local Taylor distributor can perform this winter
storage service for you.
Wrap detachable parts of the freezer, such as beater,
blades, drive shaft, and freezer door, and place them
in a protected dry place. Rubber trim parts and
gaskets can be protected by wrapping them with
moisture-proof paper. All parts should be thoroughly
cleaned of dried mix or lubrication, which attract mice
and other vermin.