Chapter 3│Drive Installation

3.1 Installation Environment

To ensure the optimum drive performance, install the AC drive in a proper environment
specified below.
Environment
Area of Use
Indoors
Ambient
Temperature
Humidity
Storage
-20°C to +60°C
Temperature
Surrounding
Area
Up to 1000 m without derating. Up to 2000 meters with 1% rated current
Altitude
derated for every 100 m counted from 1000 m.
Vibration
Enclosure
IP20
-10°C to +50°C (IP20 enclosure)
Do not install the drive in environments with wide temperature fluctuations
so as to ensure the drive reliability.
When the drive is installed in an enclosure cabinet, make sure the cooling
works properly to keep the temperature within the specified levels.
Do not allow the drive to freeze.
When drives are installed side-by-side in a cabinet, follow the instruction
illustrated in Figure 3.2 to ensure the air flow.
Under 90% RH
Free of condensation
Free from water, oil, metal shavings or other foreign materials.
Free from flammable materials (e.g., wood)
Free from harmful gases and liquids
Free from direct sunlight
Free from oil mist, corrosive gas, flammable gas or dust.
Free from radioactive material
Green Class 2 or above
10 to 20 Hz at 9.8 m/s2
20 to 55 Hz at 5.9 m/s2
Conditions
15