Fig. 18—Cooling Charging Chart, 582A018 Units
Fig. 20—Cooling Charging Chart, 582A030 Units
CAUTION: Errors made when reconnecting wires may
cause improper and dangerous operation. Label all wires
prior to disconnection when servicing.
The minimum maintenance requirements for this equipment are as
follows:
1. Inspect air filter(s) each month. Clean or replace when
necessary. Certain geographical locations may require more
frequent inspections.
2. Inspect indoor coil, outdoor coil, drain pan, and condensate
drain each cooling season for cleanliness. Clean at least
once per heating / cooling season or more often if needed.
C00046
Fig. 19—Cooling Charging Chart, 582A024 Units
C00043
Fig. 21—Cooling Charging Chart, 582A036 Units
3. Inspect blower motor and wheel for cleanliness at the
beginning of each heating and cooling season. Clean when
necessary. For first heating and cooling season, inspect
blower wheel bi-monthly to determine proper cleaning
frequency.
4. Check electrical connections for tightness and controls for
proper operation each heating and cooling season. Service
when necessary.
5. Ensure wires are not contacting refrigerant tubes or sharp
sheet metal edges.
6. Check and inspect heating section before each heating
season. Clean and adjust when necessary.
7. Check flue hood and remove any obstructions, if necessary.
—24—
C00042
C00044