SINGLE-PACKAGE
GAS HEATING/ELECTRIC
COOLING UNITS
UNIT 582A
Single-Package Rooftop Units with.
Direct Spark Ignition
Low Sound Levels
AFUE ratings up to 81.1%
10 SEER

AVAILABLE OPTIONS

One-piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
EASY INSTALLATION —Factory-assembled package is a com-
pact, fully self-contained, combination gas heating/electric cool-
ing unit that is pre-wired, pre-piped, and pre-charged for
minimum installation expense.
The 582A units are available in a variety of standard and optional
heating/cooling size combinations with voltage options to meet
residential and light commercial requirements. Units are light-
weight and install easily on a rooftop or at ground level. The high
tech composite basepan eliminates rust problems associated
with ground level applications.
CONVERTIBLE DUCT CONFIGURATION —Unit is designed
for easy use in either downflow or horizontal applications. Each
unit is easily converted from horizontal to downflow with addition
of two accessory duct covers.
EFFICIENT OPERATION
High-Efficiency Design offers SEER (Seasonal Energy Effi-
ciency Ratios) of 10.0 and AFUE (Annual Fuel Utilization Effi-
ciency) ratings as high as 81.1%.
Energy-Saving, Direct Spark Ignition saves gas by operating
only when the room thermostat calls for heating. Standard units
are furnished with natural gas controls. A low-cost field-installed
kit for propane conversion is available for all units.
582A units with an "N" in the thirteenth position of model num-
ber are dedicated Low NOx units designed for California instal-
lations. These models meet the California maximum oxides of
nitrogen (NOx) emissions requirement of 40 nanograms/joule or
less as shipped from the factory and MUST be installed in Cali-
fornia Air Quality Management Districts where a Low NOx rule
exists.
DURABLE, DEPENDABLE COMPONENTS
Compressors are designed for high efficiency. Each compres-
sor is hermetically sealed against contamination to help promote
longer life and dependable operation. Each compressor also has
vibration isolation to provide quieter operation. All compressors
have internal high pressure and overcurrent protection.
Monoport Inshot Burners produce precise air-to-gas mixture,
which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if
ever, requires cleaning. All gas furnace components are acces-
sible in one compartment.
Turbo-Tubular™ Heat Exchangers are constructed of alumi-
nized steel for corrosion resistance and optimum heat transfer
for improved efficiency. The tubular design permits hot gases to
make multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force
the hot gases to stay in close contact with the walls, improving
heat transfer.
Direct-Drive Multi-Speed, PSC (Permanent Split Capacitor)
Blower Motor is standard on all 582A models.
Direct-Drive, PSC Condenser-Fan Motors are designed to
help reduce energy consumption and provide for cooling opera-
tion down to 40°F outdoor temperature. Motormaster® II low am-
bient option is available as a field-installed accessory.
Refrigerant System is designed to provide dependability. Liq-
uid refrigerant strainers are used to promote clean, unrestricted
operation. Each unit leaves the factory with a full refrigerant
charge. Refrigerant service connections make checking operat-
ing pressures easier.
Evaporator and Condenser Coils are computer-designed for
optimum heat transfer and cooling efficiency. The evaporator
coil is fabricated from copper tube and aluminum fins and is lo-
cated inside the unit for protection against damage. The con-
denser coil is internally mounted on the top tier of the unit.
Copper fin coils and pre-coated fin coils are available from the
factory by special order. These coils are recommended in appli-
cations where aluminum fins are likely to be damaged due to
corrosion and are ideal for seacoast applications.
Form No. PDS 582A.18.2
Model 582A
Sizes 018-060
1-1/2 to 5 Nominal Tons
Low NOx Models Available

Advertisement

Table of Contents
loading

Summary of Contents for Bryant BRYANT 582A

  • Page 1 SINGLE-PACKAGE GAS HEATING/ELECTRIC COOLING UNITS UNIT 582A Single-Package Rooftop Units with. • Direct Spark Ignition • Low Sound Levels • AFUE ratings up to 81.1% • 10 SEER AVAILABLE OPTIONS One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance.
  • Page 2: Features

    Low Sound Ratings ensure a quiet indoor and outdoor environ- ment with sound ratings as low as 7.5 bels. (See ARI capacity charts for individual values.) Easy-to-Service Cabinets provide easy single-panel acces- sibility to serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level installation with or without a mounting pad.
  • Page 3 UNIT 582A NOMINAL TONS 018040 024040 024060 030040 030060 036060 036090 042060 042090 048090 048115 048130 060090 060115 060130 LEGEND Bels – Sound Levels (1 bel = 10 decibels) – Dry Bulb SEER – Seasonal Energy Efficiency Ratio – Wet Bulb *Air Conditioning &...
  • Page 4 UNIT SIZE 582A 018040 NOMINAL CAPACITY (ton) OPERATING WEIGHT (lb) COMPRESSOR(S) – QUANTITY REFRIGERANT Quantity (lb) REFRIGERANT METERING DEVICE Orifice ID (in.) .034 CONDENSER COIL Rows—Fins/in. 1—17 Face Area (sq ft) CONDENSER FAN Nominal Cfm 2000 Diameter Motor Hp (Rpm) EVAPORATOR COIL Rows—Fins/in.
  • Page 5 FACTORY-INSTALLED OPTIONS Louvered Grille provides hail guard and vandalism protection. A wire grille is standard on all models. See model number no- menclature for louvered grille options. Coil Options include copper/copper and vinyl-coated construc- tion for refrigerant coils. Units are shipped standard with copper tube/aluminum fin construction.
  • Page 6 OPTIONS AND ACCESSORIES (cont) Economizer Filter Rack REPLACEMENT PANEL MANUAL OUTSIDE AIR HOOD DAMPER BLADE Manual Outdoor Air Damper...
  • Page 7 REQ'D CLEARANCES FOR OPERATION AND SERVICING. in. (mm) Evaporator coil access side ....36 (914) Power entry side (except for NEC requirements) ..36 (914) Unit top .
  • Page 8 REQ'D CLEARANCES FOR OPERATION AND SERVICING. in. (mm) Evaporator coil access side ....36 (914) Power entry side (except for NEC requirements) ..36 (914) Unit top .
  • Page 9 UNIT SIZE ODS ORDER NUMBER 582A CPRFCURB006A00 018-042 CPRFCURB007A00 FLAT CURB CPRFCURB008A00 048,060 CPRFCURB009A00 NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied as required to unit being installed. 3. Dimensions in [ ] are in millimeters. 4.
  • Page 10 I DETERMINE COOLING AND HEATING REQUIRE- MENTS AT DESIGN CONDITIONS: Given: Required Cooling Capacity (TC) ..34,000 Btuh Btuh Sensible Heat Capacity (SHC) ..25,000 Btuh Btuh Required Heating Capacity .
  • Page 11 582A018 TEMP (F) OUTDOOR-AIR ENTERING CONDENSER 15.7 13.5 1.75 14.5 13.0 1.82 13.3 12.4 1.88 12.0 11.8 1.95 582A024 TEMP (F) OUTDOOR-AIR ENTERING CONDENSER 22.6 19.2 2.38 21.3 18.7 2.50 19.8 18.1 2.61 18.3 17.4 2.69 582A030 TEMP (F) OUTDOOR-AIR ENTERING CONDENSER 26.4...
  • Page 12 582A036 TEMP (F) OUTDOOR-AIR ENTERING CONDENSER 31.8 29.1 3.48 30.2 28.4 3.66 28.5 27.6 3.86 26.6 26.6 4.01 582A042 TEMP (F) OUTDOOR-AIR ENTERING CONDENSER 38.9 35.6 4.08 36.5 34.5 4.34 33.8 33.1 4.53 31.3 31.3 4.73 582A048 TEMP (F) OUTDOOR-AIR ENTERING CONDENSER 42.9...
  • Page 13 582A060 TEMP (F) OUTDOOR-AIR ENTERING CONDENSER 53.9 48.8 6.12 50.7 47.4 6.44 47.2 45.7 6.75 43.7 43.7 7.08 LEGEND Ewb – Entering Wet-Bulb – Total Unit Power Input SHC – Sensible Heat Capacity (1000 Btuh) – Total Capacity (1000 Btuh) (net) NOTES: 1.
  • Page 14 DRY COIL AIR DELIVERY*—HORIZONTAL AND DOWNFLOW DISCHARGE 230 AND 460 VOLT Unit Motor 582A Speed Watts 1082 Watts — — Watts High 1270 Watts Watts 1220 Watts High 1475 Watts Watts 1220 Watts High 1475 Watts 1430 Watts 1720 Watts High 1800 Watts...
  • Page 15 0.077 0.100 0.127 0.065 0.080 0.097 0.084 * As the height above sea level increases, there is less 0.100 0.177 0.103 † Orifices available through your local Bryant dealer. 0.120 0.138 0.088 0.100 0.113 0.108 0.120 0.132 582A 51.6 56.7 52.2...
  • Page 16 TOP COVER *NEC – National Electrical Code TYPICAL PIPING AND WIRING Vertical Discharge RETURN FROM GAS LINE Horizontal Discharge *NEC - NATIONAL ELECTRICAL CODE Horizontal Discharge INDOOR THERMOSTAT FROM POWER SOURCE DISCONNECT PER NEC*...
  • Page 17: Application Data

    CONDENSATE TRAP —A 2-in. condensate trap must be field supplied. DUCTWORK —Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. TO CONVERT A UNIT TO DOWNFLOW DISCHARGE — Units are equipped with factory-installed inserts in the down-flow openings.
  • Page 18 TYPICAL WIRING SCHEMATIC, 582A018-060; 208/230-1-60...
  • Page 19 TYPICAL WIRING SCHEMATIC, 582A030-060; 208/230-3-60 — Adjustable Heat Anticipator — Blower Relay — Contactor — Capacitor COMP — Compressor Motor — Combustion Relay — Centrifugal Switch EQUIP — Equipment — Fusible Link — Fuse — Ground — Gas Valve — Gas Valve Relay —...
  • Page 20 TYPICAL WIRING SCHEMATIC, 582A036-060; 460-3-60 — Adjustable Heat Anticipator — Blower Relay — Contactor — Capacitor COMP — Compressor Motor — Combustion Relay — Centrifugal Switch EQUIP — Equipment — Fusible Link — Fuse — Ground — Gas Valve — Gas Valve Relay —...
  • Page 21 VOLTAGE UNIT RANGE SIZE V-PH-Hz 582A 208/230-1-60 208/230-1-60 208/230-1-60 208/230-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 208-230/1/60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 LEGEND — Full Load Amps — Locked Rotor Amps — Minimum Circuit Amps MOCP — Maximum Overcurrent Protection —...
  • Page 22 OPERATING SEQUENCE Heating — When the thermostat calls for heating, terminal “W” is energized, starting the induced-draft motor. When the hall- effect sensor on the induced-draft motor senses that it has reached the required speed, the burner ignition sequence be- gins.
  • Page 23 SIZE RANGE: 1 TO 5 TONS, NOMINAL COOLING 40,000 TO 130,000 BTUH, NOMINAL HEATING INPUT BRYANT MODEL NUMBER: 582A PART 1 — GENERAL SYSTEM DESCRIPTION Outdoor rooftop mounted or ground level installed, gas heating/electric cooling unit utilizing a hermetic compres- sor for cooling duty.