Density Test Menu - Sony DFR-E3000 Operation Manual

Sdds recorder system
Hide thumbs Also See for DFR-E3000:
Table of Contents

Advertisement

Available languages

Available languages

Density Test Menu

Save Parameters button
Click to save the parameters in the specified file in the hard disc.
Parameters save to the hard disc are as follows:
Header and Footer Sequence parameters, Header Start position, and
Header End position in Density Patch Control column.
Note that the previously saved parameters are overwritten by the new
parameters.
Note
The following parameters are not saved to the hard disc:
Footer Start position and Footer End position in Density Patch Control
column.
Prior to recording, you can do a density test in order to set the LED power
to its optimum level. In this test, a user-defined test pattern sequence is
recorded onto the film repeatedly, with an increase in LED power with
each successive image. This test is required only when the current LED
power setting seems to be inappropriate.
Pattern White is a mode used to record on the negative film with a fixed
level of LED power. The film recorded in this mode is used to verify the
development process in film laboratories.
Defining the test pattern sequence
1
Select the pattern from the leftmost Pattern box in the Test Pattern
Setting column.
2
Select the duration from the leftmost Duration box in the Test Pattern
Setting column.