Packet Type; Packet Size - Siemens SIMATIC NET IE/AS-INTERFACE LINK PN IO Manual

Table of Contents

Advertisement

5 Display / WBM Configuration
5.2.11.2

Packet Type

WBM: "Packet Type" Tab − received packets sorted according to type
The "Packet Type" page displays how many frames of the type unicast, multicast,
and broadcast were received at each port.
Clicking on the "Reset" button resets this counter. If you click on an entry in the
Port column, the "Graphic statistics: Packet Type" page is displayed for the
selected port. You then see a configurable graphical representation of the counter
value.
Parameter
Port
LAN interface of the IE/AS-i LINK (1 or 2)
Unicast
Number of packets to the unicast recipient address
Multicast
Number of packets to the multicast recipient address
Broadcast
Number of packets to the broadcast recipient address
5.2.11.3

Packet Size

WBM: "Packet Size" Tab − received packets sorted according to length
This page displays how many packets of which size were received.
If you click on an entry, the "Graphic statistics: Packet Size" page is displayed for
the selected port. You then see a configurable graphical representation of the
counter value.
Parameter
Port
LAN interface of the IE/AS-i LINK (1 or 2)
64
Number of packets with 64 bytes
65−127
Number of packets with 65−127 bytes
128−255
Number of packets with 128−255 bytes
256−511
Number of packets with 256−511 bytes
512−1023
Number of packets with 512−1023 bytes
1024−1518
Number of packets with 1024−1518 bytes