Siemens SIMOTION Function Manual page 130

Motion control basic functions for modular machines
Hide thumbs Also See for SIMOTION:
Table of Contents

Advertisement

Appendix
A.4 Storing configuration files for SIMOTION D4xx devices up to kernel version V4.1.4
5. The PC with the SIMOTION SCOUT engineering system is connected to the SIMOTION
6. The PC is included in the network of the SIMOTION device (e.g. with NetPro).
7. A read/write device for the memory card is connected to the PC.
Procedure
1. Insert the memory card in the SIMOTION device and switch it on.
2. Execute the following steps in succession in the SIMOTION SCOUT engineering system:
3. Switch off the SIMOTION device and remove the memory card.
4. In the Windows Explorer in the directory for uncompressed configuration files (e.g. D:
5. Copy the configuration files from the memory card to the selected directory:
6. Repeat steps 1 to 5 for all devices, other than the device that represents the initial
130
device (e.g. via PROFIBUS).
– Select the appropriate device in the project navigator.
– Select the Edit > Open object menu to open the HW configuration of the device.
– In the HW Config program, select the Target system > Load to module menu to load
the hardware configuration to the device.
Then exit the HW Config program.
The appropriate device is still selected in the project navigator of the SIMOTION SCOUT
engineering system.
– In the SIMOTION SCOUT engineering system, select the Project > Connect to target
system menu.
– Select the Target system > Load > Load CPU / drive unit to target device menu to load
the configuration data to the device.
– Select the Target system > Copy RAM to ROM menu to store this data on the memory
card.
– Select the SINAMICS_Integrated element below the respective device in the project
navigator.
– Select the Target system > Load > Load CPU / drive unit to target device menu to load
the drive data to the device.
– Select the Target system > Copy RAM to ROM menu to store this data on the memory
card.
– Select the Project > Disconnect from target system menu.
\modular_machine\download), select the DExxxxxx folder whose hexadecimal
number you want to use to identify the configuration in the file name (xxxxxx).
– Insert the memory card into a card reader on your PC.
– Copy the USER directory from the memory card (e.g. B:\USER) to the selected directory
DExxxxxx. Overwrite any existing USER directory.
configuration.
Proceed as described above for the initial configuration, but copy the USER directory from
the memory card (e.g. B:\USER) to the INITIAL directory.