5. Press the 3 key, and the Enter key.
[
Main Menu
1. Remote Box Setup
2. External Alarm Setup
3. AMS Setup
4. Management Profile Setup
Enter JOB No.:
6. Press appropriate numeric key (1 to 4), then press the Enter key.
To return to the [AMS Setup Menu], press the E key at the setting window.
1 key: [Mode Setup]
Set the alert mode.
[Legacy]: Select when no AMS/BAM is
connected.
[AlertIF1]: Select when AMS is connected.
[AlertIF2]: Select when BAM is connected.
For [AlertIF1], the option window shown
to the right is displayed. To return to the
[AMS Setup Menu] from this window,
press the E key twice.
[Distress Alarm Stop Enable]: The AMS
can stop the alarm sound when the Dis-
tress Priority message is received.
[Distress Alarm Stop Disable]: The AMS can not stop the alarm sound when a
Distress Priority message is received.
For [AlertIF2], the option window shown
to the right is displayed. To return to the
[AMS Setup Menu] from this window,
press the E key twice.
Select the appropriate BAM unit to setup.
The [AlertIF2 Setup] option window
shown to the right is displayed.
Set the SFI for the connected BAM
unit.
Command Window
]
[
Mode Setup
1. Legacy
2. AlertIF1
3. AlertIF2
E: Exit
Enter AMS Mode No.:
3. INITIAL SETTINGS
Command Window
[
Mode Setup
]
1. Legacy
ON
2. AlertIF1
3. AlertIF2
E: Exit
Enter AMS Mode No.:
Command Window
Command Window
[
Mode Setup
]
1. Legacy
ON
[
AlertIF1 Option
]
2. AlertIF1
1. Distress Alarm Stop Enable
E: Exit
2. Distress Alarm Stop Disable
Enter AMS Mode No.:
E: Exit
Enter AlertIF1 Option No.:
Command Window
Command Window
[
Mode Setup
]
1. Legacy
ON
[
AlertIF2 Setup
]
2. AlertIF1
1. BAM SFI1 XX9999
3. AlertIF2
2. BAM SFI2 XX9999
E: Exit
E: Exit
Enter AMS Mode No.:
Enter AlertIF2 Option No.:
Command Window
Command Window
]
ON
[
AlertIF2 Option
]
Command Window
1. BAM SFI1 XX9999
[
BAM SFI Setup
]
2. BAM SFI2 XX9999
SFI1
XX9999
E: Exit
Enter AlertIF2 Option No.:
E: Exit
C: Clear
Enter SFI:
ON
3-7