External Connections - Follett Horizon Chewblet 1810 Series Installation Instructions Manual

Ice machine with ride technology
Table of Contents

Advertisement

Connect utilities to louvered docking assembly.
7.1
Water and drain
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
Cornelius • RIDE Technology
Minimum 8"
radius
2 ft. x 1" OD
.
.
.
remote condensing

External connections

7.2
Refrigerant
• Braze supplied quick-connect lines onto
stub-ins
.