Special Shutdown - Ricoh Type M3 Field Service Manual

Smart operation panel
Hide thumbs Also See for Type M3:
Table of Contents

Advertisement

3. The power LED blinks.
4. The power LED turns off.

Special Shutdown

To facilitate maintenance, the following two shutdown procedures are provided:
1. Maintenance shutdown (shortens shutdown time)
When the Quick Startup Mode is set, preparations for the next start-up are performed during
shutdown, so shutdown takes more time than in normal start-up mode. If the power is switched OFF
by the following steps, even if the Quick Startup Mode is set, the same shutdown is performed as in
normal mode (shutdown time is shortened).
Procedure: Press the power button while holding the "Stop" key until the shutting down message
shows up.
2. MFP version update shutdown (screen remains energized)
When the MFP controller or engine firmware version is updated, if shutdown and start-up of the
Android screen take time, working efficiency decreases. Therefore, by performing the following
procedure, the MFP controller/engine can be powered off alone without completely shutting down
the Android screen.
Procedure: Press the power button while holding the "Back" key until the shutting down message
shows up.
• After shutdown is completed by this procedure, when the MFP is left for 5 minutes or longer, it
starts up in normal startup mode the next time that the power is switched ON.
Power Supply Control
25