6.2 Ambient conditions

6.2
Ambient conditions
Climatic ambient conditions
The temperature values have been checked in accordance with IEC 60068-2-1, IEC 60068-
2-2 and IEC 60068-2-14. For permissible mounting positions, see "Permitted mounting
positions (Page 23)".
Operation
Storage/transport
Gradient
Relative humidity
Barometric pressure
* BIOS Power switch set to "High temperature" and USB load max. 1 W.
56
Operation
Storage/transport
Operation/storage/transport
Standard mounting position (interfaces top / bottom)
CPU Intel Atom E3930: 0 °C to 50 °C / 55 °C *
CPU Intel Atom E3940: 0 °C to 45 °C / 50 °C *
Vertical mounting (interface front; Basic device) /
Wall mounting or mounting on a standard rail (interfaces on side) /
Vertical mounting standard rail (interfaces top / bottom)
CPU Intel Atom E3930: 0 °C to 45 °C / 50 °C *
CPU Intel Atom E3940: 0 °C to 40 °C / 45 °C *
Basic device: Vertical mounting standard rail (interfaces front)
CPU Intel Atom E3930: 0 °C to 35 °C / 40 °C *
CPU Intel Atom E3940: 0 °C to 35 °C / 40 °C *
-20 ... +60 °C
Operation: Max. 10 °C/h
Storage: 20 °C/h, no condensation
Tested in accordance with IEC 60068-2-78, IEC 60068-2-30
5 ... 85 % at 30 °C, no condensation
5 ... 95 % at 25/55 °C, no condensation
1080 to 660 hPa, corresponds to an elevation of -1000 to 3500 m