Mechanical ambient conditions
Vibration resistance
Operation
Storage/transport
Impact resistance
Operation
Storage/transport
6.3

Power demand of the components

Maximum power consumption of the auxiliary components
Auxiliary components
USB device 3.0
Note
Device can overheat!
The power supply cannot make unlimited power available. The auxiliary components
consume energy and produce heat.
The device may overheat. The auxiliary components will be damaged.
SIMATIC IPC127E
Operating Instructions, 01/2019, A5E44296915-AA
Tested in accordance with IEC 60068-2-6
With wall or vertical mounting:
5 to 9 Hz: 3.5 mm
9 to 500 Hz: 9.8 m/s
With standard mounting rail or vertical standard mounting rail:
10 ... 58 Hz: 0.0375 mm
58 ... 200 Hz: 4.9 m/s
5 to 9 Hz: 3.5 mm
9 to 500 Hz: 9.8 m/s
Tested in accordance with IEC 60068-2-27
150 m/s
, 11 ms
2
250 m/s
, 6 ms
2
Maximum permitted power
consumption +5 V
High current
900 mA
Technical specifications
6.3 Power demand of the components
2
2
2
Max. total power
5 W (for all USB devices)