Panasonic SA-MAX9000GN Service Manual page 15

Hide thumbs Also See for SA-MAX9000GN:
Table of Contents

Advertisement

6.3.2.
Doctor Mode Table 2
Mode Name
Volume Setting
To check the volume setting of the
Check
main unit.
FL Display Check
To check the FL segment display.
All segments will light up while all LED
blink at 0.5s intervals.
Traverse Test
To determine the traverse unit
operation for inner & outer access track.
In this mode, ensure the CD is in the
main unit.
Reliability Test
To determine the traverse unit
(Combination)
operation & open/close operation of the
mechanism.
In this mode, ensure the CD is in the
main unit.
Loading Test
To determine the open & close
operation of the CD Mechanism Unit.
In this mode, the tray will open & close
automatically.
Item
Description
FL Display
Press [7]: VOL50
Press [8]: VOL35
Press [9]: VOL0
The counter will
increment by one.
When reach 99999999
will change to 00000000
Cancellation Display
The counter will
increment by one.
When reach 99999999
will change to 00000000
Cancellation Display
The counter will
increment by one.
When reach 99999999
will change to 00000000
Cancellation Display
15
Key Operation
Front Key
In Doctor Mode:
1. Press [7], [8], [9] button on
the remote control.
Volume
In Doctor mode:
1. Press [1] button on the
remote control.
2. To cancel this mode, press
[0] button on the remote
control.
In Doctor Mode:
1. Press [10]
[1]
on the remote control.
2. To cancel this mode, press
[0] button on the remote
control.
In Doctor Mode:
1. Press [10]
[1]
on the remote control.
2. To cancel this mode, press
[0] button on the remote
control.
In Doctor Mode:
1. Press [10]
[2]
on the remote control.
2. To cancel this mode, press
[0] button on the remote
control.
[2] button
[5] button
[1] button

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-max9000puSb-max9000gn

Table of Contents