Siemens Sinumerik 840D sl Diagnostic Manual page 507

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Remedy:
For 840D:
Match _CVAL entry to the number of existing probe and calibration block data fields, that means:
- Adapt _TP[ ]/_CVAL[0] field size, or
- Adapt _WP[ ]/_CVAL[1] field size, or
- Adapt _KP[ ]/_CVAL[2] field size, or
- Adapt _TWP[ ]/_CVAL[3].
For 840D sl:
Check machine data for the number of probe and calibration block data fields, that means:
- Workpiece probe
- Calibration block
- Workpiece probe in MCS 51602$MNS_MEA_CAL_TP_NUM or
- Workpiece probe in WCS 51603$MNS_MEA_CAL_TPW_NUM
61417
[Channel %1: ] Block %2: Probe will collide with the carrier of the
reference groove.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE973
Remedy:
Take up collision-free initial position of the axes involved in the measuring process.
61418
[Channel %1: ] Block %2: Protocol file too small, check MD11420:
LEN_PROTOCOL_FILE.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycle: CYCLE106
Remedy:
Check MD11420: LEN_PROTOCOL_FILE.
61419
[Channel %1: ] Block %2: Check probe calibration with reference to
center of ball/circumference of ball.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE974, CYCLE994, CYCLE977,
CYCLE978, CYCLE979, CYCLE997, CYCLE998
Remedy:
The workpiece probe must be calibrated according to its use in the measuring cycles.
61420
[Channel %1: ] Block %2: Check calibration of multi/mono probes.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE974, CYCLE994, CYCLE977,
CYCLE978, CYCLE979, CYCLE997, CYCLE998
Remedy:
The workpiece probe must be calibrated according to its type and use.
61421
[Channel %1: ] Block %2: Software release of measuring cycles or NCK
inadequate or set up incorrectly --> error code %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy:
Causes of error:
1. Error code = A
61422
[Channel %1: ] Block %2: Parameter _MVAR incorrect --> Error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE996
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
51600$MNS_MEA_CAL_WP_NUM or
51601$MNS_MEA_CAL_EDGE_NUM or
->
_OVR[] - parameter field too small. Check GUD definition.
DEF CHAN REAL _OVR[72] (up to MZ06.03.xx.xx =32)
Overview of Alarms