Siemens Sinumerik 840D sl Diagnostic Manual page 954

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
SINAMICS-Alarms
Cause:
An error has occurred in while accessing via the internal TM I2C bus.
Remedy:
Replace the Terminal Module.
234903
<location>VSM: I2C bus error occurred
Message
-
value:
Drive object:
A_INF, B_INF, S_INF
Reaction:
NONE
Acknowledge:
NONE
Cause:
An error has occurred in while accessing via the internal TM I2C bus.
Remedy:
Replace Voltage Sensing Module (VSM).
234904
<location>VSM: EEPROM
Message
-
value:
Drive object:
CU_CX32, CU_I, CU_LINK, CU_S, HUB, SERVO, TB30, TM15, TM15DI_DO, TM17, TM31, TM41,
TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
An error has occurred accessing the non-volatile memory on the Terminal Module.
Remedy:
Replace the Terminal Module.
234904
<location>VSM: EEPROM
Message
-
value:
Drive object:
A_INF, B_INF, S_INF
Reaction:
NONE
Acknowledge:
NONE
Cause:
An error has occurred accessing the non-volatile memory on the Terminal Module.
Remedy:
Replace Voltage Sensing Module (VSM).
234905
<location>VSM: Parameter access
Message
-
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
The Control Unit attempted to write an illegal parameter value to the Voltage Sensing Module (VSM).
Remedy:
- check whether the firmware version of the VSM (r0158) matches the firmware version of Control Unit
(r0018).
- if required, replace the Voltage Sensing Module.
Note:
The firmware versions that match each other are in the readme.txt file on the memory card.
234920
<location>VSM: Temperature sensor fault
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
When evaluating the temperature sensor, an error occurred.
Alarm value (r2124, interpret decimal):
1: Wire breakage or sensor not connected (KTY: R > 1630 Ohm).
2: Measured resistance too low (PTC: R < 20 Ohm, KTY: R < 50 Ohm).
Remedy:
- check that the sensor is connected correctly.
- replace sensor.
2-954
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG 2009 All Rights Reserved
03/2009