Siemens SINAMICS Series Equipment Manual page 300

Booksize power modules
Hide thumbs Also See for SINAMICS Series:
Table of Contents

Advertisement

Cabinet Configuration and EMC Booksize
7.4 Arrangement of components and devices
For modules with a width of between 150 and 300 mm, the distance between the upper and
lower module row must be at least 500 mm.
Caution
Signal cables must not be routed parallel to power cables.
Wiring rules for DRIVE-CLiQ
See the Commissioning Manual.
Overview of the DC link supply adapter and DC link adapter
DC link supply adapter (cable outlet on top)
6SL3162-2BD00-0AAx
6SL3162-2BM00-0AAx
DC link adapter (cable outlet on side)
6SL3162-2BM01-0AAx
Note
The current carrying capacity of the DC link busbars must be taken into account. For the
specifications, see the technical specifications for the module.
7-18
Suitable for module width:
50 mm, 100 mm
150 mm, 200 mm, 300 mm
all
Max. connectable cross-
section
10 mm
2
95 mm
2
95 mm
2
Equipment Manuel for Booksize Power Modules
Manual, (GH2), Edition 06.2005, 6SL3097-2AC00-0BP2
Max. current carrying capacity
36 A
240 A
240 A