Using Monitor Mode; Operation Monitor - Mitsubishi FX3U-20SSC-H Quick Start Manual

Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

Servo ///
Motion ///
Save the project.
To perform the table operation:
Select 'XY-axis table operation' in the X-axis Pattern drop-down menu of the Position
start tab. Set the Table operation start No. as desired (0 in this example) and begin
positioning by pressing the Start button, 'Yes,' and 'OK.'

4.4 Using Monitor Mode

4.4.1 Table Monitor
To use table monitor during positioning, first enable the XY-operation Table pattern in
TEST MODE and begin its operation by following Section 4.3: To perform the table
operation above. Do not stop the operation. Ensure that the 'XY-axis Table information'
window is open and click on the Monitor button
Monitor → Monitor On/Off.]

4.4.2 Operation Monitor

To use operation monitor during positioning, first enable the XY-operation Table pattern
in TEST MODE and begin its operation by following Section 4.3:To perform the table
operation above. Do not stop the operation. Instead, click on the Close button to exit the
X-axis Operation test window.
Press the Test On/Off button
off. Double-click on 'Operation monitor' in the 'File data list' panel on the left-hand side.
Click on the Monitor Start button and experiment with the X-axis Operation status and Y-
axis Operation status buttons to monitor axis control data such as target addresses and
operation speeds and servo status. By clicking on the Signal button, the FX3U-20SSC-H
monitor data can be displayed for useful feedback. The Operation Monitor is also helpful
for determining positioning errors.
Mitsubishi Electric Europe B.V. /// FA-European Business Group /// Gothaer Strasse 8 /// D-40880 Ratingen /// Germany
Tel: (02102) 4860 /// Fax: (02102) 486112 /// Email:info@mitsubishi-automation.com /// Web: www.mitsubishi-automation.com
Servo ///
Motion ///
in the Test toolbar and click 'Yes' to turn TEST MODE
Servo ///
Motion ///
These parameters do
not need to be written to
the 20SSC-H again.
Uncheck this setting
unless you want data to
be written to the Flash
ROM.
in the Test toolbar or go to [Online →
Servo ///
Motion ///
Servo

Advertisement