Installation - Kenwood NX-200 Service Manual

Vhf digital transceiver
Hide thumbs Also See for NX-200:
Table of Contents

Advertisement

NX-200(G)
4. Power ON the target transceiver.
5. Connect the cloning cable (part No. E30-3325-05) to the
universal connectors on the source and target.
6. Press the [ ] key on the source while the source displays
"CLONE MODE". The data of the source is sent to the
target. While the target is receiving the data, "PROGRAM"
is displayed. When cloning of data is completed, the
source displays "END", and the target automatically oper-
ates in the User mode. The target can then be operated
by the same program as the source.
7. The other target can be continuously cloned. When the
[ ] key on the source is pressed while the source displays
"END", the source displays "CLONE MODE". Carry out
the operation in step 4 to 6.
Note:
• Cannot be cloned if the password (overwrite password) is
programmed to the target.
• "Model Name" must be same to clone the transceiver.
Preparation before Installing Option board
■ Removing the GPS PCB
1. Remove the two screws from the cover.
2. Remove the cover by inserting the tip of a pair of twee-
zers into the screw hole of the cover and prying it open.
6
REALIGNMENT
8. Firmware Version Information
Press and hold the [Side1] key while turning the trans-
ceiver power ON and then keep pressing and holding the
[Side1] key, the fi rmware version information appears on the
LCD.