■ Relay hardware (E29-1242-04) installation procedure
1. Fit one side of the relay hardware to a right corner of the
chassis using a pair of tweezers a .
2. Fit the other side of the relay hardware to the rib of the
chassis b .
a
b
■ Changing the channel selector from 16-channel
operation to free
1. Remove the channel selector knob.
2. Remove the circular nut.
3. Remove the mechanical stopper.
4. Reassemble the circular nut and channel selector knob
that were removed in steps 1 and 2, in their original posi-
tions.
Channel selector knob
(K29-9408-13)
Circular nut
(N14-0844-04)
DISASSEMBLY FOR REPAIR
Mechanical stopper
(D32-0446-14)
■
Forming the GPS coaxial cable(E37-1716-05)
Form the GPS coaxial cable as shown in the fi gure.
NX-200(G)
11