STEP 26S
SERVICE ALARM
BOTH
SET
STEP 27S
SCHEDULED SERVICE
0.25
YR
SET
STEP 28S
SCHEDULED SERVICE
80000
GAL
SET
RETURN TO NORMAL MODE
To reset diagnostic data push "Next" &  button until TYPE appears in window, then press " & " button simultaneously for 3 seconds
or until screen changes.
DAYS SINCE REGEN
2
DAY
SINCE LAST REGEN
342
GAL
RESERVE HISTORY
0 160
DAY
GAL
13

SERVICE REMINDER

STEP 26S – Set scheduled service display using  or  buttons. Available options are OFF, TIME,
ON GAL or BOTH. Selecting OFF disables this feature. If OFF is selected, press NEXT to exit
System Setup. If TIME, ON GAL or BOTH is selected press NEXT to select the TIME and/or ON
GAL values. See Steps 27S and/or 28S. This can also activate relay if Service Alarm is selected
on Step 21S. Press REGEN to return to the previous step.
STEP 27S – Service alarm for TIME ranges from 0.25 to 9.75 years. Press  and  buttons to-
gether until "SET" appears, use arrows to set. Press NEXT to either exit System Setup or if BOTH
was selected go to Step 28S. When time selected and days remaining falls below 1 year, display
following will show "scheduled service in xxx days" so technician can reset to pre-programmed
time if desired. Press REGEN to return to the previous step.
STEP 28S – Service alarm for ON GAL ranges from 100 to 9,999,900 gallons. Press  and 
buttons together until "SET" appears, use arrows to set. Press NEXT to exit System Setup. Press
REGEN to return to the previous step.
Reset service reminder by holding down up and down arrows together when reminder is displayed.
STEP 1D – Press  or  simultaneously for three seconds. If screen in step 2D does not appear
STEP 1D
in 5 seconds the lock on the valve is activated.
STEP 2D – Days, since last regeneration: This display shows the days since the last regenera-
STEP 2D
tion occurred. Press the NEXT button to go to Step 3D. Press REGEN to exit Diagnostics.
STEP 3D – Volume, since last regeneration: This display shows gallons of water that has been
STEP 3D
treated since the last regeneration. This display will equal zero if a water meter is not installed.
Press the NEXT button to go to Step 4D. Press REGEN to return to previous step.
STEP 4D – Volume of reserve capacity used for last 7 days: If the unit is set up as a softener,
STEP 4D
a meter is installed and Set Volume Capacity is set to "Auto", this display shows 0 day (for today)
and the reserve capacity. Pressing the  button will show day 1 (which would be yesterday) and
displays the reserve capacity. Pressing the  button again will show day 2 (the day before yes-
terday) and the reserve capacity. Keep pressing the  button to show the capacity for days 3, 4,
5 and 6. The  button can be pressed to move backwards in the day series. Press NEXT button
at any time to go to Step 5D. Press REGEN to return to previous step.

DIAGNOSTICS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents