Agilent Technologies 54621A Programmer's Manual page 94

Mixed-signal oscilloscopes
Hide thumbs Also See for 54621A:
Table of Contents

Advertisement

Programmer's Quick Reference
Commands and Queries
Command
:DISPlay:DATA [format][,][area]
<display data>
:DISPlay:LABel {{0 | OFF} | {1 | ON}} :DISPlay:LABel?
:DISPlay:LABList #80000524
<binary block>
:DISPlay:PERSistence <value>
:DISPlay:SOURce <value>
:DISPlay:VECTors {{1 | ON} | {0 | OFF}} :DISPlay:VECTors?
*DMC <macro label>,<macro
definition>
*EMC {{0 | OFF} | {1 | ON}}
*ESE <mask>
:EXTernal:BWLimit <bwlimit>
:EXTernal:IMPedance <value>
:EXTernal:PROBe <attenuation>
:EXTernal:PROTection[:CLEAR]
:EXTernal:RANGe
<range>[<suffix>]
:EXTernal:UNITs <units>
n/a
:FUNCtion:CENTer <frequency>
:FUNCtion:DISPlay {{0 | OFF} | {1 |
ON}}
:FUNCtion:OFFSet <offset>
:FUNCtion:OPERation <operation> :FUNCtion:OPERation?
8-6
Query
:DISPlay:DATA? [format][,][area] <format> ::= {TIFF} (command only)
:DISPlay:LABList?
:DISPlay:PERSistence?
:DISPlay:SOURce?
n/a
*EMC?
*ESE?
:EXTernal:BWLimit?
:EXTernal:IMPedance?
:EXTernal:PROBe?
:EXTernal:PROTection?
:EXTernal:RANGe?
:EXTernal:UNITs?
*ESR?
:FUNCtion:CENTer?
:FUNCtion:DISPlay?
:FUNCtion:OFFSet?
Options and Query Returns
<area> ::= {GRATicule} (command only)
<format> ::= {TIFF | BMP} (query only)
<area> ::= {GRATicule | SCReen} (query only)
<display data> ::= data in IEEE 488.2 # format
{0 | 1}
<binary block> ::= a time-ordered list of 75 labels. Each label can
be a maximum of 6 characters followed by a comma.
<value> ::= {MINimum | INFinite}}
<value> ::= {PMEMory{0 | 1 | 2}}
{1 | 0}
<macro label> ::= quoted ASCII string
<macro definition> ::= block data in IEEE 488.2 # format
{0 | 1}
<mask> ::= 0 to 255; an integer in NR1 format
Bit
Weight Enables
7
128
PON - Power On
6
64
URQ - User Request
5
32
CME - Command Error
4
16
EXE - Execution Error
3
8
DDE - Device Dependent Error
2
4
QYE - Query Error
1
2
TRG - Trigger Query
0
1
OPC - Operation Complete
<bwlimit> ::= {0 | OFF}
<impedence> ::= {ONEMeg} for 54620-series
<impedence> ::= {ONEMeg | FIFTy} for 54640-series
<attenuation> ::= probe attenuation ratio in NR3 format
{NORM | TRIP}
<range> ::= vertical full-scale range value in NR3 format
<suffix> ::= {V | mV}
<units> ::= {VOLTs | AMPeres}
<status> ::= 0 to 255; an integer in NR1 format
<frequency> ::= the current center frequency in NR3 format.
The range of legal values is from 0 Hz to 25.00 GHz.
{0 | 1}
<offset> ::= the value at center screen in NR3 format.
The range of legal values is +/-10 times the current sensitivity of
the selected function.
<operation> ::= {SUBTract | MULTiply | INTegrate | DIFFerentiate
| FFT}

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

54624a54622a54641a54621d54622d54641d ... Show all

Table of Contents