Agilent Technologies 54621A Programmer's Manual page 103

Mixed-signal oscilloscopes
Hide thumbs Also See for 54621A:
Table of Contents

Advertisement

Command
:TRIGger:GLITch:RANGe
<greater than time> [suffix],
<less than time> [suffix]
:TRIGger:GLITch:SOURce <source> :TRIGger:GLITch:SOURce?
:TRIGger:HFReject {{0 | OFF} | {1 |
ON}}
:TRIGger:HOLDoff <holdoff_time> :TRIGger:HOLDoff?
:TRIGger:IIC:PATTern:ADDRess
<value>
:TRIGger:IIC:PATTern:DATA
<value>
:TRIGger:IIC:[SOURce:]CLOCk
<source>
:TRIGger:IIC:[SOURce:]DATA
<source>
:TRIGger:IIC:TRIGger:QUALifier
<value>
:TRIGger:IIC:TRIGger[:TYPE]
<type>
:TRIGger:LIN:SIGNal:BAUDrate
<baudrate>
:TRIGger:LIN:SIGNal:DEFinition
<value>
:TRIGger:LIN:SOURce <source>
:TRIGger:LIN:TRIGger <condition> :TRIGger:LIN:TRIGger?
:TRIGger:MODE <mode>
:TRIGger:NREJect {{0 | OFF} | {1 |
ON}}
:TRIGger:PATTern <value>,
<mask> [,<edge source>, <edge>]
:TRIGger:SEQuence:COUNt
<count>
Query
:TRIGger:GLITch:RANGe?
:TRIGger:HFReject?
:TRIGger:IIC:PATTern:ADDRess? <value> ::= integer or <string>
:TRIGger:IIC:PATTern:DATA?
:TRIGger:IIC:[SOURce:]CLOCk?
:TRIGger:IIC:[SOURce:]DATA?
:TRIGger:IIC:TRIGger:QUALifer?
:TRIGger:IIC:TRIGger[:TYPE]?
:TRIGger:LIN:SIGNal:BAUDrate? <baudrate> ::= {2400 | 9600 | 19200}
:TRIGger:LIN:SIGNal:DEFinition?
:TRIGger:LIN:SOURce?
:TRIGger:MODE?
:TRIGger:NREJect?
:TRIGger:PATTern?
:TRIGger:SEQuence:COUNt?
Programmer's Quick Reference
Options and Query Returns
<greater than time> ::= start time from 10 ns to 9.99 seconds in
NR3 format
<less than time> ::= stop time from 15 ns to 10 seconds in NR3
format
[suffix] ::= {s | ms | us | ns | ps}
<source> ::= {CHANnel<n> | EXTernal} for 546xxA;
<source> ::= {CHANnel<n> | DIGital0,...,DIGital15 } for 546xxD
<n> ::= 1-2 or 1-4 in NR1 format
{0 | 1}
<holdoff_time> ::= 60 ns to 10 s in NR3 format
<string> ::= ""0xnn"" n ::= {0 ,...., 9 | A ,...., F}
<value> ::= integer or <string>
<string> ::= ""0xnn"" n ::= {0 ,...., 9 | A ,...., F}
<source> ::= {CHANnel<n> | EXTernal} for 546xxA
<source> ::= {CHANnel<n> | DIGital0,...,DIGital15 } for 546xxD
<n> ::= 1-2 or 1-4 in NR1 format
<source> ::= {CHANnel<n> | EXTernal} for 546xxA
<source> ::= {CHANnel<n> | DIGital0,...,DIGital15 } for 546xxD
<n> ::= 1-2 or 1-4 in NR1 format
<value> ::={EQUal | NOTequal | LESSthan | GREaterthan}
<type> ::= {STARt | STOP | READ7 | READEeprom | WRITe7 |
WRITe10 | NACK | RESTart}
<value> ::= {LIN | RX | TX}
<source> ::= {CHANnel<n> | EXTernal} for 546xxA
<source> ::= {CHANnel<n> | DIGital0,...,DIGital15} for 546xxD
<n> ::= 1-2 or 1-4 in NR1 format
<condition> ::= {SYNCbreak}
<mode> ::= {EDGE | GLITch | PATTern | CAN | DURation | IIC |
SEQuence | SPI | TV | USB}
<return_value> ::= {<mode> | <none>}
<none> ::= query returns "NONE" if the :TIMebase:MODE is ROLL
or XY
{0 | 1}
<value> ::= 32-bit integer or <string>
<mask> ::= 32-bit integer or <string>
<string> ::= "0xnnnnnn"; n ::= {0,...,9 | A,...,F}
<edge source> ::= {DIGital0,..,DIGital15 | CHANnel<n> | NONE}
<edge> ::= {POSitive | NEGative}
<n> ::= 1-2 or 1-4 in NR1 format
<count> ::= integer in NR1 format
Commands and Queries
8-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

54624a54622a54641a54621d54622d54641d ... Show all

Table of Contents