Monitor Output - Omron Omnus FND-X Series User Manual

Position drivers
Table of Contents

Advertisement

Application
4-3

Monitor Output

The Position Driver outputs (analog) a voltage proportional to the motor's rotation speed
and current. The monitor voltage is output from the monitor output terminal on the front
panel of the Position Driver. This analog output can be used to install a meter in the con-
trol panel or to provide more precise gain adjustments.
H Monitor Output Terminal on Driver's Front Panel
H Monitor Output Circuitry
H Monitor Output Specifications
Speed monitor
With 0 V as center, voltage output at rate of 3 V/(motor's rated speed).
Forward rotation: (+) voltage; reverse rotation: (–) voltage output
Output accuracy: approx. ±10%
Current monitor
With 0 V as center, voltage output at rate of 3 V/(motor's maximum current).
Forward acceleration: (+) voltage; reverse acceleration: (–) voltage
Output accuracy: approx. ±10%
4-8
Monitor output
terminal
Speed monitor / Current monitor
Chapter 4
2 (Speed monitor / Current monitor)
1 (GND)