W20000-en.book Page 47 Monday, October 22, 2007 3:35 PM
Indicators
There are three indicators which show the status of the projector. Check the following for information about the
indicator lights. If there is anything wrong, turn the projector off and contact your dealer.
When the projector is in a normal state, ...
Power
Temp
Red
Red
Orange
Off
Green
Off
Flashing
Green
Off
Orange
Off
Flashing
When the projector is in an abnormal state, ...
Power
Temp
Off
Off
Orange
Off
Off
Red
Off
Red
Off
Red
Off
Red
Off
Green
Off
Green
Off
Orange
Red
Red
Red
Red
Red
Red
Green
Red
Green
Red
Green
Red
Orange
Red
Orange
Red
Orange
Red
Off
Orange
Lamp
Status & Description
Red
Main power switch on
Off
Stand-by mode
Off
Powering up
Off
Normal operation
•
The projector needs 90 seconds to cool down as it was
abnormally shut down without the normal cooling down
process.
Off
•
The projector needs to cool for 90 seconds after the power is
turned off.
Lamp
Status & Description
•
The lamp has been damaged. Please contact your local BenQ
Red
customer center for purchasing a new lamp.
•
The lamp is not properly attached.
Red
•
The lamp has been damaged. Please contact your local BenQ
customer center for purchasing a new lamp.
Off
Red
The fans are not working.
Green
Orange
Red
Fan sensors error
Orange
Fans do not rotate during
Red
powering up.
Red
Green
Orange
Thermal condition error
Red
Green
Orange
Red
The internal temperature is too high.
Green
•
The intake ventilation or the exhaust ventilation is blocked.
•
The projector may be in a poorly ventilated location.
Orange
•
The ambient temperature may be too high.
The dust filter is seriously clogged with dust. The projector is going to
Green
shut down.
The projector has shutdown
automatically. If you try to re-
start the projector, it will
shutdown again. Please contact
your dealer for assistance.
47