5-7. List of errors

Error
Description of error
code
E000
Execution of data initial-
ization (This is not an
error.)
E007
Motor overload
E009
Overtime of solenoid
energization
E011
Media is not inserted
E012
Read error
E013
Write error
E014
Write protect
E015
Format error
E016
External media over-ca-
pacity
E019
File size over
E022
File undetected
E024
Pattern data size error
E032
File compatibility error
E071
Motor output connector
slip-off
E072
Motor overload when the
thread trimmer operates
E079
Overload operation error • Load applied to the main shaft motor is
Cause
• The existing control box has been re-
moved and a new one is mounted.
• In the case the initialization operation is
executed.
• In the case the machine head is locked.
• In the case of sewing extra-heavy weight
material that exceeds the guaranteed
material thickness.
• In the case the motor fails to rotate.
• In the case of the motor or driver failure.
• In the case the length of solenoid ener-
gizing time has exceeded the assumed
one.
• In the case no media is inserted.
• In the case data stored on the media
cannot be read.
• In the case data cannot be written on
the media.
• In the case the media is placed in the
write-prohibition state.
• In the case formatting of the media can-
not be carried out.
• In the case the capacity of media is not
enough.
• In the case of attempting to read the
custom pattern data or condensation
custom data which exceeds the max-
imum permissible data size into the
memory of sewing machine from the
USB thumb drive.
• In the case of attempting to read a file
which is not stored in the USB thumb
drive into the operation panel.
• In the case the number of stitches con-
tained in data is too large when attempt-
ing to read the condensation custom
pattern data from the USB thumb drive.
• In the case the file is not compatible.
• In the case the motor connector has
slipped off.
• Same as E007.
excessively large.
– 98 –
Item to be checked
This is not a failure.
• Check whether the pulley is entan-
gled with thread.
• Check whether the motor output con-
nector (4P) has loosened.
• Check whether the motor can be
turned smoothly by hand.
• Turn the power OFF and check for a
media.
• Turn the power OFF and check for a
media.
• Turn the power OFF and check for a
media.
• Turn the power OFF and check for a
media.
• Turn the power OFF and check for a
media.
• Turn the power OFF and check for a
media.
• Turn the power OFF and check the
USB thumb drive.
• Turn the power OFF and check for a
media.
• Check for looseness and slip-off of
the motor output connector.
• Same as E007.

Hide quick links: