7
To post the the first LCM in the frame or cabinet, type
> POST LCM 0 0
and press the Enter key.
Example of a MAP display:
PM
LCM
LCM
HOST 00 0
Unit0:
InSv
Unit1:
InSv
Drwr:
01
23
..
..
Both units use ringing generator 0 (RG-0).
8
Are the units in the LCM aligned to use RG-0?
If both LCM units
are aligned and both use RG-0
are not aligned or both do not
use RG-0
9
To get an LCM unit to use RG-0, type
> SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number you want to switch to RG-0 (0 or 1)
If the SWRG does not pass, contact ETAS and do not continue with this
procedure.
Example of a MAP display:
swrg unit 0
LCM HOST 00 1 Unit 0 SWRG Passed
Note: Perform this step for each LCM unit that needs to use RG-0.
10
To busy unit 1 of the first LCM, type
> BSY UNIT 1
and press the Enter key.
Example of a MAP response:
SysB
ManB
0
0
0
0
InSv
Links_OOS: CSide
/RG: 0
/RG: 0
11
11
11
45
67
89
10
23
45
..
..
..
..
..
..
Ringing in Series II peripherals 3-29
OffL
CBsy
ISTb
0
0
3
0
0
0
0 , PSide
0
11
11
RG: Pref 0 InSv
67
89
Stby 1 InSv
..
..
Do
step 10
step 9
DMS-100 Ringing System
InSv
39
4