18
To exit table LCMINV, type
> QUIT ALL
and press the Enter key.
19
To access the PM level of the MAP terminal, type
> MAPCI;MTC;PM
and press the Enter key.
20
To post and return to service the LCM unit, type
> POST LCM RLCM 0 0
and press the Enter key.
> RTS UNIT 1
and press the Enter key.
21
The following steps complete the procedure for RG-0.
22
Are the units in the LCM aligned to use RG-1?
If both LCM units
are aligned and both use RG-1
are not aligned or both do not
use RG-1
23
To get an LCM unit to use RG-0, type
> SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number you want to switch to RG-1 (0 or 1)
Example of a MAP response:
swrg unit 1
LCM RLCM 00 0 Unit 1 SWRG Passed
Note: Perform this step for each LCM unit that needs to use RG-1.
24
To test the LCM unit and ringing generator, type
> TST UNIT 1
and press the Enter key.
25
To busy unit 0 of the LCM, type
> BSY UNIT 0
and press the Enter key.