Procedure 3-2 Single LCM ringing generator configuration change procedure
At the MAP terminal
1
To access table LCMINV, type
> TABLE LCMINV
and press the Enter key.
2
To position on the tuple for the LCM, type
> POS RLCM 0 0
and press the Enter key.
Example of a MAP display
>POS RLCM 0 0
RLCM
00 0
RLCM
N
3 256K 256K
LCM Y
For more information about ringing types, refer to the Customer Data Schema
Reference Manual and chapter "DMS-100 ringing overview" in this document.
3
Check the RNGTYPE for the LCM. The previous example shows a
RNGTYPE of frequency selective.
4
To quit the table, type
> QUIT ALL
and press the Enter key.
5
To access the PM level of the MAP terminal, type
> MAPCI;MTC;PM
and press the Enter key.
Example of a MAP display:
PM
6
To post the LCM, type
> POST LCM RLCM 0 0
and press the Enter key.
Example of a MAP display
4
1
P
29 6X04AA XLCM11BD
F REA
20
30
40
50 HLCM
RNGTYPE is set to frequency selective (F).
SysB
ManB
0
0
Ringing in Series II peripherals 3-39
(16)(18)(17)(19)$
OffL
CBsy
0
0
DMS-100 Ringing System
LTC
0
IsTb
InSv
0
39