Ringing Generator Status - Nortel DMS-100 Series General Description Manual

Ringing system
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

situation, the ringing resources are tied up unnecessarily for the duration of
RNG_TMEOUT_NO_OF_SEC, when other ringing requests may be blocked.
To avoid this, set RNG_TMEOUT_NO_OF_SEC to as short a period as
practical.
Bad CP IO msg
The bad-CP-IO-msg log accompanies LINE logs 205, 205, and 206. It
indicates the DMS-100 central control (CC) has received a corrupted message
from the PM. The report indicates the line equipment number (LEN)
associated with the faulty line and can be used to troubleshoot ringing
complaints. This log is usually associated with the LINE113 log. A description
of the LINE113 log is in Log Report Reference Manual.

Ringing generator status

Ringing generator status can be determined when the MAP terminal is in the
display or no display mode. The following example shows a posted LCM and
reveals the status of the ringing generators adjacent to the drawer numbers with
the MAP terminal in the display mode.
CM
MS
.
.
LCM
0 Quit
2 Post_
3 ListSet
4 SwRg_
5 Trnsl_ Unit0: ISTb
6 Tst
7 Bsy_
8 RTS_
9 OffL_
10 LoadPM_
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
userid
Time 09:52
When the MAP terminal is in the no-display mode, operating company
personnel can enter the QUERYPM command after the LCM is posted and
obtain the status of the ringing generators for that LCM. The following MAP
display is in response to the QUERYPM command.
IOD
Net
PM
.
.
.
SysB
ManB
OffL
PM
2
LCM
0
LCM HOST 00 0
ISTb
Unit1: ISTb
Drwr: 01 23 45 67 89 01 23 45 67 89
.. .. .. .. .. .. .. .. .. ..
>
DMS-100 Family DMS-100 Ringing System BASE15 and up
Ringing system maintenance 5-5
CCS
Lns
Trks
.
.
.
CBsy
ISTb
0
21
1
0
4
0
Links OOS: Cside 0 Pside 0
/RG: 0
/RG: 0
11 11 11 11 11 RG: Pref 0 InSv
Ext
APPL
.
.
InSv
35
46
10
4
Stby 1 InSv

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dms-100

Table of Contents