Enter Y to continue processing the change request and press the Enter key.
Example of a MAP responce:
LCMTYPESEL: LCM
Example of a MAP responce:
Press the Enter key to leave this entry as it is.
Example of a MAP responce:
RGEQUIP: Y
Press the Enter key to leave this entry as it is.
Example of a MAP responce:
RNGTYPE: F
Enter UNASSIGNED and press the Enter key.
Press Enter when the system prompts you to change the value of other fields
in the tuple. This avoids making any other changes. The system will prompt
you to verify the change. See the following MAP response.
TUPLE TO BE CHANGED:
HOST
00 0
N
5 256K 256K
LCM Y
ENTER Y TO CONFIRM, N TO REJECT OR E TO EDIT.
Enter Y to confirm the tuple change request and press the Enter key.
22
Immediately position on the second LCM. Type
> POS HOST 0 1
and press the Enter key.
23
To perform a static data update (NILCHANGE), type
> CHA
and press the Enter key.
Example of a MAP responce:
ENTER Y TO CONTINUE PROCESSING OR N TO QUIT
Enter Y to continue processing the change request and press the Enter key.
Press the Enter key as a response to the system prompts. When you press
Enter with no change to the values, you avoid changing any values in the
tuple. The NILCHANGE request updates static data in the LCM units.
Example of a MAP display:
TUPLE TO BE CHANGED:
HOST
00 0
N
5 256K 256K
LCM Y
F BOC 20 30 40 50 HLCM
ENTER Y TO CONFIRM, N TO REJECT OR E TO EDIT.
Enter Y and press the Enter key to confirm the NILCHANGE request.
24
Repeat steps 20 and 21 on the first LCM, but enter the desired value in field
RNGTYPE instead of UNASSIGNED.
25
Repeat steps 22 and 23 to perform another static data update (NILCHANGE)
on the second LCM.
LCE
4
1
N
UNASSIGNED
HLCM
LCE
4
1
N
Ringing in Series II peripherals 3-33
26 6X04AA XLCM11BD
( 0) ( 2) ( 1) ( 3)$
26 6X04AA XLCM11BD
( 0) ( 2) ( 1) ( 3)$
DMS-100 Ringing System
LGC
0
LGC
0