Pentair FLECK 5800 LXT Installer Manual page 29

Hide thumbs Also See for FLECK 5800 LXT:
Table of Contents

Advertisement

Salt amount
[g/L
]
resin
170
200
230
260
290
To calculate the system mass capacity:
M
= V
x C
capacity
resin
resin ex
To calculate the system combined capacity:
C
= V
x C
capacity
resin
cor resin ex
To calculate the system volume capacity:
V
= M
/ TH
capacity
capacity
or
V
= C
/ TH
capacity
capacity
Caution
If a mixing device is set on the valve before meter, TH = TH
Having determined the previous capacity allows the operator to know the service cycle duration.
Ref. MKT-IM-005 / C - 22.05.2018
Corresponding resin exchange
capacity in [g/L
58.5
62.7
66.9
71
75.3
inlet
inlet
Installer Manual Fleck 5800 - LXT - System sizing
] as CaCO
[per L
resin
3
with:
M
: system mass capacity [g as CaCO 3 ]
capacity
V
: volume of resin [L]
resin
C
: resin exchange capacity [g/L
resin ex
with:
C
: system combined capacity [°f.m
capacity
V
: volume of resin [L]
resin
: corresponding resin exchange 
C
cor resin ex
3
capacity [°f.m
/l or °dH.m
with:
V
: system volume capacity [m
capacity
M
: system mass capacity [g as CaCO
capacity
C
: system combined capacity [°f.m
capacity
TH
: inlet water hardness [mg/L as CaCO 3 or °f or °dH]
inlet
3
°f.m
°dH.m
]
[per L
resin
5.85
3.27
6.27
3.5
6.69
3.74
7.1
3.97
7.53
4.21
as CaCO
resin
3
or °dH.m
3
/l]
3
]
]
3
3
or °dH.m
- TH
.
INLET
OUTLET
3
]
resin
]
3
3
]
3
]
29 / 88