Kenwood TK-3148 Service Manual page 42

Uhf fm transceiver
Hide thumbs Also See for TK-3148:
Table of Contents

Advertisement

TK-3148
Item
Condition
6. DQT
1) Adj item [BAL]
Balance
Adjust [ *** ]
Adjust
Deviation meter fi lter
[Narrow]
LPF: 3kHz
HPF: OFF
2) Adj item
[L BAL] → [C BAL] → [H BAL]
Adjust [ *** ]
PTT: ON
[Wide]
3) Adj item [w BAL]
Adjust [ *** ]
PTT: ON
7. Max DEV
1) Adj item [MAX]
Adjust
Adjust [ *** ]
[Narrow]
AG: 1kHz/150mV
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
2) Adj item
[L MAX] → [C MAX] → [H MAX]
Adjust [ *** ]
PTT: ON
[Wide]
3) Adj item [w MAX]
Adjust [ *** ]
PTT: ON
8. MIC
[Panel Test Mode]
Sensitivity
1) CH-Sig: 1-1
Check
AG: 1kHz/Narrow 15mV
Wide 12mV
Deviation meter fi lter
LPF: 15kHz
PTT: ON
9. QT
1) Adj item [QT]
Deviation
Adjust [ *** ]
Adjust
Deviation meter fi lter
[Narrow]
LPF: 3kHz
HPF: OFF
2) Adj item
[L QT] → [C QT] → [H QT]
Adjust [ *** ]
PTT: ON
[Wide]
3) Adj item [w QT]
Adjust [ *** ]
PTT: ON
10. DQT
1) Adj item [DQT]
Devition
Adjust [ *** ]
Adjust
Deviation meter fi lter
[Narrow]
LPF: 3kHz
HPF: OFF
2) Adj item
[L DQT] → [C DQT] → [H DQT]
Adjust [ *** ]
PTT:ON
[Wide]
3) Adj item [w DQT]
Adjust [ *** ]
PTT: ON
42
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
Panel
ANT
Panel
meter
Deviation
Universal
meter
connector
Oscilloscope
AG
AF VTVM
Panel
Adjustment
Parts
Method
Encoder
Make the demodu-
knob
lation waves into
square waves
1.85kHz
±50Hz
(According to the
larger+,-)
4.20kHz
(According to the
larger+,-)
Check
Narrow 1.0~2.2kHz
Wide 2.4~3.6kHz
Encoder
0.35kHz
±50Hz
knob
0.75kHz
0.35kHz
0.75kHz
Specifi cations / Remarks