Installation - Smeg SE900 Instruction Manual

Smeg electric oven instruction manual
Table of Contents

Advertisement

2
2.1
Check that mains voltage and power cable ratings are as per the
indications provided on the label attached to the oven door frame.
This label must never be removed.
It is obligatory for the electrical system to be grounded according to the
methods required by safety rules.
If a plug and socket connection is being used make sure that the plug
and socket are compatible. Avoid use of adapters and shunts as these
could cause overheating and risk of burns.
If a fixed connection is being used fit power line with an omnipolar circuit
breaker with a contact opening gap equal to or greater than 3 mm in an
easily accessible position in proximity to the oven.
Remove rear cover by loosening relevant screws to gain access to the
terminal strip. Secure power cable to oven by means of the appropriate
fitting.
If the power cable is replaced, the wire
section on the new cable must not be
less than 1.5 mm
keeping in mind that the end to be
connected to the hob must have the
ground wire (yellow-green) longer by
at least 20 mm.
The manufacturer declines all responsibility for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.
24
Instructions for the installer

INSTALLATION

Electrical connection
2
(3 x 1.5 cable),