Performance Monitor Setting - JRC JMA-9133-SA Installation Manual

Marine radar equipment
Hide thumbs Also See for JMA-9133-SA:
Table of Contents

Advertisement

JMA-9100/7100 Installation Manual > 4.INITIAL SETTING > 4.10 PERFORMANCE MONITOR SETTING
4.10

PERFORMANCE MONITOR SETTING

When the following units are replaced, adjust the performance monitor according
to the procedures shown in this section.
• Performance monitor
• Scanner unit
[I] Receiving monitor adjustment (MON Adjustment)
Make adjustments of the circuit that monitors the reception performance of the
radar apparatus.
Procedures
1)
When the radar apparatus has an inter-switch function, make settings for a
master display unit.
2)
Open the [Service Man Menu] screen.
3)
Open the [4.MON Adjustment] screen according to the operation shown below.
4)
Increase or decrease the adjustment value so that the farthest end of the
MON pattern is 18.0 nm.
1. Adjust Menu
→ 4. TXRX Adjustment
→ 4. MON Adjustment
Increase or decrease the
adjustment value so that the
farthest end of the MON
pattern is 18.0 nm
MON pattern
Fig 4-4:
MON adjustment
4- 16