14 | Recording
14.2.5 Recording diagnosis
14.2.6 Displaying online recording diagnosis
114 / 148
The channel 'statectrl_ok' of the DDU 9 can be used for online monitoring of recording
status.
Bit
Value
0
1
1
2
2
4
3
8
4
16
5
32
6
64
7
128
Content of status bits
Name
Bitset
RECORD
Measurement data is re-
corded.
DATAOK
Received data without
error.
BLKOK
All measurement blocks
have been set up cor-
rectly.
STARTED A measurement has
been set up.
('statectrl_ok')
1.
To add a Recording Diagnosis element to a measurement sheet, change to page "Cal-
ibration/Measuring" and drag a 'Bit-LED' element from the Toolbox and drop it on
measurement sheet.
2.
Drag channel 'statectrl_ok' from the Data Area and drop it on the 'Bit-LED' element.
DDU 9
Name
RECORD
DATAOK
BLKOK
-
-
-
STARTED
-
Bit cleared
No measurement data will be stored because meas-
urement thresholds are not reached.
Discarding received data because of wrong
timestamps. Check wiring of SYNC signal.
Some measurement blocks have not been set up
correctly.
A measurement is not set up. Either no recording
configuration has been found or logger software
upgrade is not activated.