system. You must enter a Technician ID and
a Lead ID in order to use this menu.
1
--Image Sensor Setup
An Image Sensor daughterboard is required
to enable Image Sensor capabilities on the
module. This menu is only active if an
Image Sensor daughterboard is connected.
1
--- Learn Image Sensor
Press "OK" to enter Add Mode. Enroll the
Image Sensor by inserting batteries or
resetting.
1
--- Delete Image Sensor
Press "OK" and scroll to the Image Sensor
to delete. Press "OK" to delete.
1
---Image Sensor Settings
Press "OK" and scroll to the Image Sensor
of interest. Press "OK".
1
----Image Sensor #[x]
[x] is the sensor ID. Press "OK" to view
information on this Image Sensor.
1
-----[Power Information]
Gives information on the Image Sensor's
battery level and power status.
1
-----Signal
The signal strength of the communication
between the Image Sensor and the Image
Sensor daughterboard.
1
-----Test PIR
Press "OK" to put the Image Sensor in PIR
test mode.
1
-----PIR Sensitivity
Press "OK" to view current selection. Scroll
down to view available sensitivity levels.
Press "OK" to select.
-- Dealer Logo Update
This menu is used to upload a Dealer logo
to the two-way talking touchscreen
(2WTTS). (Only available for dealers who
have set up this feature with Alarm.com.)
Press OK. If a logo is NOT available for
upload to the 2WTTS, you will see "Logo
update not available". If a logo is available,
you will be asked to wait until the panel's
LEDs start flashing, then wait until the
panel's LEDs stop flashing – at which time
the logo should show on the 2WTTS.
System Test + Installer
Scroll down to System Test. Enter the
Code
installer code and press OK
- Interactive Services
Scroll up to Interactive Services and press
OK
-- Sensor Reporting Test
This menu is used to automate the process
of testing that all sensors report correctly
to the Central Station. It will put the
account on test and request the list of
sensors that did not report correctly. It is
available only to installers who have
integrated their sensor testing process with
the Central Station and with Alarm.com
-- AVM/CDMA Test
This menu is used to automate the process
of testing AVM over the CDMA link. It is
available only to installers who have
integrated their wireless AVM testing
process with the Central Station and with
Alarm.com
-- CDMA Module Status
See Installer Programming section above.
System Test + Master Code
Scroll down to System Test. Enter the
master code and press OK
- Interactive Services
Scroll up to Interactive Services and press
OK
-- CDMA Module Status
See Installer Programming section above.
Simon XT/XTi GSM Module V4 Installation Instructions
-- Z-Wave Setup
See Installer Programming section above.
-- Thermostat Settings
This menu is used to troubleshoot the
interaction between Z-Wave thermostats
and the two-way wireless talking touch
screen (2WTTS).
--- Thermostat 1, 2, 3
Select the thermostat and press OK..
---- Node ID
The Z-Wave node id of the Z-Wave
thermostat. If 0, then the Z-Wave
thermostat been found. You may need to
troubleshoot the Z-Wave network via the Z-
Wave Setup menu. Press OK to have the
module try to find the thermostat again.
---- Mode
The Z-Wave thermostat's current mode
(Off, Heat, Cool)
---- Setpoints
The current heating and cooling setpoints
of the Z-Wave thermostat. These are the
temperature thresholds that determine
when the heating or cooling unit will turn
on.
---- Fan
The current fan mode (Auto, On))
---- Schedules
Shows whether the thermostat is running
on a schedule (On), or is using a fixed
setpoint. Note that these thermostat
schedules must be set from the Alarm.com
website. Some Z-Wave thermostats allow
setting schedules directly at the
thermostat. These built-in schedules cannot
be set or controlled via the website or via
the touch screen (2WTTS).
---- Update 2WTTS
Press OK to force an update of the
thermostat information shown on the
touch screen (2WTTS). Note that these
updates may take several minutes to
complete. To speed up the process, go into
System Programming. This puts the panel in
high-speed communication mode with the
touch screen.
---- Remove From 2WTTS
To remove the association between the Z-
Wave thermostat and the touch screen
(2WTTS). This will hide the Thermostat
page on the 2WTTS.
---- Last Temp. Read
For troubleshooting only. Shows how many
unsuccessful attempts were made by the
CDMA module at trying to communicate
with the Z-Wave thermostat. A low number
of 0 or 1 is normal.
-- Request Weather Update
Press OK if the weather forecast is not
showing on the (2WTTS). This menu is
available only on firmware versions 144c
and later and only if a is learned into the
panel.
All Image Sensor menus are only available when an Image Sensor
daughterboard has been connected to the module. An Image Sensor
daughterboard is required to enable Image Sensor functionality.
2
TM
Refer to the emPower
installation instructions and guides on the
Alarm.com Dealer Site for more information on Z-Wave enrollment and
troubleshooting.