8.3
Quick Commissioning NX (topology takeover)
Introduction
You have completed a topology takeover of the associated drive components for the NCU.
You have inserted a NX in the HW Config for the NCU.
If you change to the "Drive system" menu with the <Recall> key, you will get an overview of
the associated components.
The NX ("CU_CX32_126") is he only drive system which does not yet have any sub-
ordinated drive components (see following figure).
Figure 8-8
You have the following two options to execute topology recognition for additional drive
modules.
• Topology recognition via the "Drive system" menu
• Topology recognition via the "Drive units" menu
Operating sequences via the "Drive system" menu
1. Select the NX with the cursor keys (e.g. "CU_CX32_126").
2. Press the "Drive units" softkey.
3. Start the topology takeover queries by clicking on "OK" twice.
CNC Part 1 (NCK, PLC, drive)
Commissioning Manual, 11/2006, 6FC5397-2AP10-2BA0
"Drive systems" menu after topology matching
The HMI recognizes, that topology takeover has not yet taken place.
Quick Commissioning starts.
Commissioning SINAMICS drives
8.3 Quick Commissioning NX (topology takeover)
67