5. SPECIFICATIONS OF ELECTRICAL PARTS
Outdoor Unit
No.
Parts name
1
Compressor
2
Outdoor fan motor
3
High pressure switch
4
PMV-Coil
5
Coil-value-4way
6
Reactor
P.C.board for control and fan motor drive
7
8
P.C.board for compressor drive
9
Outdoor temp. sensor (TO sensor)
10
Discharge temp. sensor (TD sensor)
11
Suction temp. sensor (TS sensor)
Heat exchanger sensor (TE sensor)
12
13
Heat exchanger sensor (TL sensor)
14
Fuse (Mounted on P.C.board, MCC-1626)
15
Fuse (Mounted on P.C.board, MCC-1626)
16
Fuse (Mounted on P.C.board, MCC-1626)
17
Fuse (Mounted on P.C.board, MCC-1627)
Fuse (Mounted on P.C.board, MCC-1627)
18
19
PTC Thermistor
Type
RX330A2T-20M
WDF-340-A100-1
ACB-4UB83W
CAM-MD12TCTH-7
STF-H01AJ1872A1
CH-55-2Z-T
MCC-1626
MCC-1627
—
—
—
—
—
50T 100H
FJL 250V 6.3A
SCT 3.15A
50T(P) 063HFGF-001C4
GAC1 31.5A
MZ32-101RMARD01E
- 25 -
FILE NO.SVM-18044
Specifications
Output 3000W
Output 100W
ON : 3.2MPa, OFF : 4.15MPa
DC12V
AC220V ~ 240V
5.4~6.14mH, 14A
—
—
10 kΩ at 25°C
50 kΩ at 25°C
10 kΩ at 25°C
10 kΩ at 25°C
50 kΩ at 25°C
T10A, 250V
T6.3A, 250V
3.15A, 250V
T6.3A, 250V
31.5A, 500V
100Ω, 500V