No.
Part name
High
9
1. Detachment
pressure
1) Recover the refrigerant gas.
switch
2) Carry out works of 1 of 1.
3) Remove the inverter cover.
4) Cut the bundling bands that fixate high
5) Remove the connector for high pressure
6) Remove the High pressure switch.
Procedure
Remove screws between the inverter
cover and the inverter box.
(ST1T Ø4 × 10, 2 pcs)
pressure switch lead line.
switch from the inverter.
∗ Cautions when assembling the high
pressure switch
∗ Tighten the high pressure switch with
11±1N•m.
∗ Tightening work must use two
spanners.
High pressure switch connector
Inverter
High pressure switch
- 77 -