Vertex Standard VX-131 Service Manual page 18

Fm business two-way radio, vhf model
Hide thumbs Also See for VX-131:
Table of Contents

Advertisement

Alignment
RX Sensitivity
Set the transceiver to "CH 3 (173.995 MHz)" via the
"
CH
" box.
Injust a 160.005 MHz siganl at a level of 40dBµ with
±3.0 kHz deviation with a 1 kHz to the Antenna Jack.
Double click the left mouse button on the "
tivity
" parameter to open the pop-up window.
Move the Slide bar, as need, to tune for best sensitiv-
ity; ultimately, the transceiver should be aligned so
that the RF Signal Generator output level is –6 dBµ
EMF (0.25 µV) or less for 12 dB SINAD.
Click the the left mouse button on the [
in the new data.
18
Threshold NSQ Level (Wide)
RX Sensi-
OK
] box to lock
Set the transceiver to "CH 2 (160.005 MHz/Wide)" via
the "
CH
" box.
Injust a 160.005 MHz siganl at a level of –10dBµ with
±3.0 kHz deviation with a 1 kHz to the Antenna Jack.
Double click the left mouse button on the "
NSQ Level
" parameter to open the pop-up window.
Move the Slide bar from the Value "
position which the LED indicator on the transceiver's
top panel will blinks green.
Click the the left mouse button on the [
in the new data.
Threshold
0
" position to the
OK
] box to lock

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vx-132

Table of Contents