11.4.1 Overview Of The Default And Application Settings - Siemens XC1003-A Technical Manual

Extinguishing control unit
Table of Contents

Advertisement

Programming the user functions

11.4.1 Overview of the default and application settings

Step
Function
1
Change the activated time of
control line 4
Change the function of control
line 5
2
Change the flooding time of
control line 4
Change the flooding time of
control line 5
3
Change the function of contact 1
Change the function of contact 3
Change the function of contact 2
Change the function of LED9
(Remote transmission) and
LED6 (Fire alarm)
Change the function of control
line 2
4
Change the function of
monitored input 1
Suppress the fault indication if
state "Released" is not reported
Change the function of
monitored input 2
5
Change the active mode of
control line 1
Change the active period of
control line 1
Change the active mode and
active period of control line 3
6
Enable "Alarm verification"
function of detector zones 1 and 2
Enable "Alarm verification"
function of detector zone 3
Enable "Alarm verification"
function of detector zone 4
70
Building Technologies
Fire Safety & Security Products
The following table describes the default values for the different settings.
Each country can use these application settings. We recommend that you define
your settings from this chapter.
Default setting:
Application setting Nr. 1: takes into account the additional Southwest European
Application setting Nr. 2: takes into account the Northern European national
Application setting Nr. 3: takes into account the Flemish national standards, e.g.
Application setting Nr. 4: takes into account non-EU countries with their own
Application setting Nr. 5: takes into account additional national standards, e.g.
Application setting Nr. 6: takes into account additional Northern European national
Application setting Nr. 7: takes into account EU regulations with additional national
Default
Appl.
setting
setting
Nr. 1
7
7
14
15
1
4
6
9
1
4
5
6
8, 10
8, 10
12, 15
12, 15
17
19
1
2
4
5
6
7
1, 5, 9
2, 5,10
11
11
15, 18, 20 15, 19, 20 15, 19, 22 15, 18, 20 15, 18, 20 15, 18, 20 17, 18, 20 15, 18, 20
1
1
3
3
5
5
for countries without additional national standards, e.g.
Portugal, Italy and various non-EU countries
standards, e.g. Spain
standards, e.g. Scandinavia and Sweden
Belgium and Luxembourg
national standards, e.g. Switzerland
Luxembourg and Netherlands
standards, e.g. Denmark
standards, e.g. France
Appl.
Appl.
Appl.
setting
setting
setting
Nr. 2
Nr. 3
Nr. 4
7
7
5
17
17
15
1
1
1
6
10
6
4
2
1
6
5
5
8, 10
9, 10
8, 10
12, 15
12, 15
14, 15
23
19
17
1
1
1
4
4
5
10
10
6
4, 8, 10
2, 7, 10
1, 5, 9
11
11
11
1
1
1
3
3
3
5
5
5
Appl.
Appl.
Appl.
setting
setting
setting
Nr. 5
Nr. 6
Nr. 7
7
7
7
14
15
14
1
4
1
6
9
6
4
2
3
6
6
5
9, 10
8, 10
9, 10
13, 15
12, 15
14, 15
19
17
22
1
2
1
4
4
5
7
9
6
1, 6, 10
2, 6, 10
3, 7, 10
11
12
13
1
1
1
3
3
3
5
5
5
A6V10099837_a_en
12.2007