Reload the battery
to restart!
XXXXXXXX
Reload the battery
to restart!
tskid:XXXXXXXX
ercd :XXXXXXXX
addr :XXXXXXXX
No resume info.
has been retained.
Program restarts
automatically.
System Program malfunction
Problem
During execution of System Program, the System
Program has attempted to write onto the write-pro-
tected area of the memory.
(xxxxxxxx: Error address)
If this error occurs, the BHT beeps five times
(for 0.1 second per beep).
01
Solution
Unload and reload the rechargeable battery car-
tridge, then turn on the power. If this error occurs
frequently, contact your system administrator.
Problem
During execution of System Program, the System
Program has received an invalid command code.
(xxxxxxxx: Error address)
If this error occurs, the BHT beeps five times
(for 0.1 second per beep).
02
Solution
Unload and reload the rechargeable battery car-
tridge, then turn on the power. If this error occurs
frequently, contact your system administrator.
Resume data lost
Problem
No resume data has been retained since the BHT
was not normally powered off and then left with no
battery cartridge loaded or with a discharged bat-
tery cartridge loaded even if the resume function
had been set to ON.
The BHT displays this error message for 3
seconds and automatically runs the execution
program from the point of start-up.