GE ERESCO MF4 Series Operating Manual page 58

Industry x-ray unit for digital control unit
Table of Contents

Advertisement

Copyright by GE Sensing & Inspection Technologies GmbH
58
Operating Manual ERESCO MF4 Type Series
Pin assignment X3
between
pin 1 and 4:
between
pin 2 and 5:
between
pin 3 and 5:
between
pin 6 and 5:
between
pin 1 and 4:
between
pin 2 and 5:
between
pin 3 and 5:
between
pin 6 and 5:
Pin assignment X4
for the cooling circuit
between
pin 1 and 4:
between
pin 2 and 5:
Pin assignment X5
Description
Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
PE
Pin assignment X6
between
pin 4 and 5:
between
pin 4 and 6:
Normally closed contacts should be used. The function is executed when opening the
contact, provided the other one is closed.
If only one connection (pins 4/5 or pins 4/6) is used, the other contact must be
jumpered.
Pin assignment X6
Pin 1:
Pin 2:
Pin 3:
for flash light
Jumper for operation without warning flash light
230 V AC; max. 0.5 A for prewarning time ON
230 V AC; max. 0.5 A for high voltage ON
230 V AC; max. 0.5 A; constant
or
Jumper for operation without warning flash light
115 V AC; max. 0.5 A for prewarning time ON
115 V AC; max. 0.5 A for high voltage ON
115 V AC; max. 0.5 A; constant
depending on the applied mains.
Signalling contact for the water flow rate monitor
Supply voltage for the water cooling pump
230V AC, 4A constant or 115V AC, 4A constant
depending on the applied mains.
for the connecting cable
+27V
RS485B
RS484A
+325V
-325V
GND
Protective earth
for EXTERNAL START/STOP
External START
External STOP
for interface V24
GND
TXD
RXD
Bogenstrasse 41 D - 22926 Ahrensburg
08/24/2016
6. Edition, ID No.: 37020GB-F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents