GE PFSS9PKY Technical Service Manual page 76

Profi le 29 cu. ft. bottom freezer
Hide thumbs Also See for PFSS9PKY:
Table of Contents

Advertisement

Self Diagnostics – During Normal Operation Table
LED
Item
R-1-
Icemaker Sensor Error Display error: separation of
a
R-1-
Refrigerator Sensor
b
Error
R-1-
Refrigerator Defrost
c
Sensor Error
R-1-
Refrigerator Fan Error
d
R-1-
Icemaker Error
e
R-1-
Refrigerator Defrost
g
Error
F-1-
Ambient Sensor Error
a
F-1-
Freezer Sensor Error
b
F-1-
Defrost Sensor Error
c
F-1-
Freezer Fan Error
d
F-1-
Condenser Fan Error
e
Trouble Contents
sensor housing part, contact error,
disconnection, short circuit
Display error of detecting temperature
of sensor: more than 149°F (+65°C) or
less than -58°F (-50°C)
Display error during operation of fan
motor: feed back signal line contact
error, separation of motor wire, motor
error
Display error: ice making kit is
harvested more than 3 times and level
error. Note: Apply to the applicable
icemaker model.
Display error: separation of fresh food
compartment defrost heater housing
part, contact error, disconnection,
short circuit or temperature fuse error
Display error: the fresh food
compartment defrosting does not
fi nish. Defrost is heating continuously
for more than 80 minutes.
Display error: sensor housing
separation, contact error,
disconnection, short circuit
Display error by detecting
temperature of sensor: more than
149°F (+65°C) or less than -58°F (-50°C)
Display error during operation of fan
motor: feed back signal line contact
error, motor wire separation, motor
error
Display error during operation of fan
motor: feed back signal line contact
error, motor wire separation, motor
error
– 76 –
Diagnostic Method
When checking the voltage of
MAIN PCB CN90 #3 to CN90 #4:
should be between 4.5 to 1.0V.
When checking the voltage of
MAIN PCB CN30 #6 to CN75 #1:
should be between 4.5 to 1.0V.
When checking the voltage of
MAIN PCB CN #7 to CN75 #1:
should be between 4.5V to 1.0V.
Voltage of MAIN PCB CN75
orange to gray should be
between 7v to 12V.
After replacing icemaker, check
the operation by turning the
appliance ON again.
After separating MAIN PCB
CN70, CN71, from PCB, check
the resistance value between
CN70 white to CN71 orange.
It should be 102 ohms ± 7%.
(Resistance value is varied by
the input power.) Check 0 ohm:
heater short, ∞ ohm: wire/
bimetal open.
Check the voltage of MAIN PCB
CN32 #1 to #4. It should be
between 4.5V to 1.0V.
Check the voltage of MAIN PCB
CN30 #3 to CN75 #1. It should
be between 4.5V to 1.0V.
Check the voltage of MAIN PCB
CN30 #4 to CN75 #1. It should
be between 4.5V to 1.0V.
Voltage of MAIN PCB CN75
yellow to gray should be
between 7V to 12V.
Voltage of MAIN PCB CN75 sky
blue to gray should be between
7V to 12V.
(Continued next page)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pfss9sky

Table of Contents