Download Print this page

BEA SUPERSCAN-T User Manual page 7

Presence sensor w/monitoring
Hide thumbs Also See for SUPERSCAN-T:

Advertisement

MECHANICAL
1.
The positioning of the modules within the aluminum extrusion will be as shown below. The modules will always be positioned
ADJUSTMENTS
so that the transmitter (TX) is at the leading-edge of the door. Modules may be flipped around to accommodate handing of
doors.
POSITIONING AND
ANGLING THE
MODULES
2.
The angle of each module may be set independently. Use the charts below to help determine the angling. The angles may have to be altered
once the units have been powered up and walk-tested.
75.5911.02 20180226
Ribbon Cable
Leading Edge
Side
Slave Module
TX
RX
INACTIVE ZONE (B)
DISTANCE FROM FLOOR
8"
12"
16"
20"
Approach Side
Safety Side
I
N
Ribbon Cable
P
U
T
SUPERSCAN-T ANGLE
10º
0
6"
12 ½"
0
6"
12"
0
5 ½"
11 ¼"
0
5 ¼"
10 ½"
Hinge Side
Door Cord
(must be placed on interior of door)
Slave module
Master module
Master Module
O
U
T
TX
RX
P
U
T
15º
20º
25º
19 ¼"
26"
33 ¼"
18"
24 ½"
31 ½"
16 ¾"
23 ¼"
29 ½"
16"
21 ½"
27 ½"
A
Page 7 of 9

Advertisement

loading