ACCESS CODE
The access code (1 to 4 digits) is recommended to program sensors installed close to each other.
If you forget the access code, cycle the power supply.
Within the fi rst minute, you can access the sensor without introducing any access code.
SAVING OR CHANGING AN ACCESS CODE:
DELETING AN ACCESS CODE:
TROUBLESHOOTING
The door will not
The sensor power is off.
open.
The LED is OFF.
The door will not
Improper output
close.
confi guration on the sensor.
The LED is OFF.
The door opens
The sensor is disturbed
and closes
by the door motion or
constantly.
vibrations caused by the
The blue LED is on.
door motion.
It rains and the
The sensor detects the
sensor detects for
motion of the rain drops.
no apparent reason.
The blue LED is on.
The sensor detects
Metallic environment
objects outside its
detection fi eld.
The blue LED is on.
The blue LED
The sensor needs an access
fl ashes quickly
code to unlock.
after unlocking.
The sensor does
Batteries in the remote
not respond to the
control are weak or
remote control.
installed improperly.
Remote control incorrectly
oriented.
24/7 Technical Support:
1-800-407-4545
General Technical Questions:
Tech_Services@beainc.com
The complete declaration of conformity is available by contacting BEA
75.5730.01 20120914 SPARROW
1
Check the wiring and the power supply.
1
Check the output confi guration setting on each
sensor connected to the door operator.
2
Verify door control is operational.
1
Make sure the sensor is mounted properly.
2
Make sure the detection mode is unidirectional.
3
Increase the tilt angle.
4
Reduce the fi eld size.
5
Increase the immunity fi lter.
1
Make sure the detection mode is unidirectional.
2
Increase the immunity fi lter.
3
Install the ERC (rain accessory).
1
Increase the immunity fi lter.
Decrease the fi eld size.
2
1
Enter an access code.
2
Cut and restore the power supply to access the
sensor. Change or delete the access code.
1
Check and change the batteries if necessary.
1
Point the remote control towards the sensor.
Customer Service:
1-800-523-2462
Technical Documentation:
www.beasensors.com
Page 4 of 4
DESCRIPTION
1
2
3
TECHNICAL SPECIFICATIONS
Technology:
microwave
Transmitter frequency:
24.150 GHz
Transmitter radiated power:
< 20 dBm EIRP
Transmitter power density:
< 5 mW/cm²
Detection mode:
motion
Min. detection speed:
2 in/s (measured in the sensor axis)
Supply voltage:
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
Mains frequency:
50 to 60 Hz
Max power consumption:
< 2 W
Output:
relay (free of potential change-over contact)
Max. contact voltage:
42V AC - 60V DC
Max. contact current:
1A (resistive)
Max. switching power:
30W (DC) / 60VA (AC)
Mounting height:
6.5 ft to 20 ft
Degree of protection:
IP64
Temperature range:
-22 °F to + 140 °F
Dimensions:
5.51 in (L) x 2.17 in (H) x 2.25 in (W)
Tilt angles:
0° to 90° vertical; -120° to +120° lateral
Material:
ABS
Weight:
5.8 oz
Cable length:
30 ft
Norm conformity:
R&TTE 1999/5/EC; EMC 2004/108/EC
* Other use of the device is outside the intended purpose and can not be guaranteed by the manufacturer.
75.5730.01 20120914 SPARROW
SPARROW
Motion activation sensor
for automatic industrial doors*
1.
cover
2.
main connector
3.
radar antenna
4.
DIP-switch
5.
push buttons
6.
LEDs
Specifi cations are subject to changes without prior notice.